SPECIFICATION



AC INPUT


  • AC Input Voltage 100V:76V~130V 110V:80V~138V 115V:83.5V~140V 120V:87V~140V 208V:152V~260V 220V:160V~276V 230V:167V~280V 240V:174V~280V 100V:76V~130V 110V:80V~138V 115V:83.5V~140V 120V:87V~140V 208V:152V~260V 220V:160V~276V 230V:167V~280V 240V:174V~280V
  • AC Input Frequency 50 or 60 Hz+/-3 Hz
  • AC Input Phase Single
  • AC Input Power factor >= 0.98


AC OUTPUT


  • AC Output Voltage 100V/110V/115V/120V or 208V/220V/230V/240V
  • AC Output Frequency 50 or 60 Hz +/- 0.5%
  • AC Output Voltage Regulation (+/-2%)
  • AC Output Powerfactor 0.7 (lagging)
  • AC Output Hamonic distortion <3% of T.H.D. at linear load
  • AC Output Overload detection 105% for 10 seconds and 130% +/- 10% for 300ms


PROTECTION


  • Protection Spike 320 Joules, 2ms
  • Protection EMI/RFI 10dB at 0.15 MHz, 50 dB at 30 MHz
  • Protection Overload UPS automatical shutdown if overload exceeds 110% of nominal at 20 seconds and 125% at 5 seconds.
  • Protection Short UPS output cut off immediately or input fuse(or breaker) protection
  • Protection Unit Fuse for 110V models Except 3000A, breaker for 220V models Except 1000A


EFFICIENCY


  • Field49 > 85%


TRANSFER


  • Transfer Power failure Recovery 0 ms
  • Transfer Overload Disappear Auto transfer to UPS
  • Transfer UPS to By Pass or Vice Versa N/A


PROTECTION


  • Protection Spike 150 Joules


BATTERY


  • Battery Type - Sealed lead acid battery, free-maintenance
  • Battery DC Voltage 72V
  • Battery Protection cut off without draining any current when battery low


BACKUP TIME


  • Backup Time RM Full Load 9 minutes
  • Backup Time RM Half Load 25 minutes


PHYSICAL


  • Physical Weight kgs 32
  • Physical Weight 71
  • Physical Dimension mm 192x460x385


INDICATOR


LED



ALARM


  • Alarm Battery Discharge The first warning will beep every 4 seconds to indicate battery in use. The second warning will beep every 1 second to signal battery low condition
  • Alarm UPS Fault Continuous beeping sound


INTERFACE


  • Interface Dry Contact Provide power management & diagnostic functions including power status, battery low, schedule UPS ON/OFF, battery/load level display and more. Compatatible with Windows 95/98/2000/ME/NT/XP, Novell Unix and other popular systems
  • Interface RS-232 Provide power management & diagnostic functions including power status, battery low, schedule UPS ON/OFF, battery/load level display and more. Compatatible with Windows 95/98/2000/ME/NT/XP, Novell Unix and other popular systems


ENVIRONMENT


  • Environment Temperature 0 deg C ~ 40 deg C
  • Environment Humidity 0%~95% (Non condensing)