Internet Sweepstakes ownership opportunities

Internet Sweepstakes ownership opportunities

Ink Grabber

Chinese Gadget Wholesale

eGo Portable USB3


Acceptance Mark


Picture of Powercom 4U Rackmount  Smart King XL SXL-3000ARM UPS B-Backup

Powercom 4U Rackmount Smart King XL SXL-3000ARM UPS B-Backup


Powercom 4U Rackmount Smart King XL SXL-3000ARM UPS Battery Backup
Product image Product image
Bookmark and Share

Powercom 4U Rackmount Smart King XL SXL-3000ARM UPS Battery Backup



SPECIFICATION



AC INPUT


  • AC Input Capacity on Battery 3000VA
  • AC Input Voltage (+/-) 25% at line input
  • AC Input Frequency 50 or 60 Hz+/-5Hz (auto sensing)
  • AC Input Phase Single


AC OUTPUT


  • AC Output Voltage Pure sine wave at +/-5% of nominal, -10% of nominal after low battery warning
  • AC Output Frequency 50 or 60 Hz +/- 0.5%
  • AC Output Voltage Regulation AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal. AVR decrease output voltage 13% below input voltage if +9% to +25% of nominal


PROTECTION


  • Protection Spike 320 Joules, 2ms
  • Protection EMI/RFI 10dB at 0.15 MHz, 50 dB at 30 MHz
  • Protection Overload UPS automatical shutdown if overload exceeds 110% of nominal at 20 seconds and 125% at 5 seconds.
  • Protection Short UPS output cut off immediately or input fuse(or breaker) protection
  • Protection Unit Fuse for 110V models Except 3000A, breaker for 220V models Except 1000A


BATTERY


  • Battery Type - Hot swappable, sealed, maintenance-free lead acid, with 3 - 6 year lifetime
  • Battery TypicaL 4 hours (to 90% of full capacity)
  • Battery Protection Automatic self-test & discharge protection, replace battery indicator
  • Battery Run Time 290 minutes


BACKUP TIME


  • Backup Time RM Full Load 5 ~ 6 minutes
  • Backup Time RM Half Load 17 ~ 18 minutes


PHYSICAL


  • Physical Weight kgs 47
  • Physical Weight 103
  • Physical Dimension mm 483x560x178


INDICATOR


LED



ALARM


  • Alarm Battery Backup Slow beeping sound (about 0.2 Hz)
  • Alarm Battery Low Rapid beeping sound (about 1Hz)
  • Alarm Overload Continue beeping sound


INTERFACE


  • Interface Dry Contact Sends AC fail and battery low signals, and receives shutdown signal from computer
  • Detect battery low, Schedule UPS on/off, AC input/output power status display
  • Interface Option Novell, SNMP, Windows NT, Window 95/98/2000/ME/XP


ENVIRONMENT


  • Environment Ambient 3,500 meters max. elevation, 0-95% humidity non-condensing, 0-40 deg c
  • Environment Audible Less 40dBA (1 meter from surface)


Manufacturer Warranty: 2 years