SPECIFICATION



AC INPUT


  • AC Input Capacity on Battery 3000VA
  • AC Input Voltage (+/-) 25% at line input
  • AC Input Frequency 50 or 60 Hz +/- 10% (auto sensing)
  • AC Input Phase Single


AC OUTPUT


  • AC Output Voltage Pure sine wave at +/-5% of nominal, -10% of nominal after low battery warning
  • AC Output Frequency 50 or 60 Hz +/- 0.5%
  • AC Output Voltage Regulation AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal. AVR decrease output voltage 13% below input voltage if +9% to +25% of nominal


PROTECTION


  • Protection Spike 320 Joules, 2ms
  • Protection EMI/RFI 10dB at 0.15 MHz, 50 dB at 30 MHz
  • Protection Overload UPS automatical shutdown if overload exceeds 110% of nominal at 20 seconds and 125% at 5 seconds.
  • Protection Short UPS output cut off immediately or input fuse(or breaker) protection
  • Protection Unit Breaker


BATTERY


  • Battery Type - Hot swappable, sealed, maintenance-free lead acid, with 3 - 6 year lifetime
  • Battery TypicaL 4 hours (to 90% of full capacity)
  • Battery Protection Automatic self-test & discharge protection, replace battery indicator
  • Battery Run Time 290 minutes


PHYSICAL


  • Physical Weight kgs 29
  • Physical Weight 63
  • Physical Dimension mm 483x38x130


INDICATOR


LED


  • LCD Indicators Status indicate line, bypass, inv, backup, fault. bat capacity, load capacity, I/P frequency, O/P frequency, inside temperature, fault statuts, load


ALARM


  • Alarm Battery Backup Slow beeping sound (about 0.2 Hz)
  • Alarm Battery Low Rapid beeping sound (about 1Hz)
  • Alarm Overload Continue beeping sound


INTERFACE


  • Interface Dry Contact Sends AC fail and battery low signals, and receives shutdown signal from computer
  • Detect battery low, Schedule UPS on/off, AC input/output power status display
  • Interface Option Novell, SNMP, Windows NT, Window 95/98/2000/ME/XP


ENVIRONMENT


  • Environment Ambient 3,500 meters max. elevation, 0-95% humidity non-condensing, 0-40 deg c
  • Environment Audible Less 40dBA (1 meter from surface)