AC INPUT
|
|
| AC Input Capacity on Battery |
625VA |
|
| AC Input Voltage |
110V +/- 25% at line input |
|
| AC Input Frequency |
50 or 60 Hz +/- 10% (auto sensing) |
|
|
AC OUTPUT
|
|
| AC Output Voltage |
Simulated sine wave at 110V +/- 5% |
|
| AC Output Frequency |
50 or 60 Hz +/- 1Hz |
|
| AC Output Voltage Regulation |
AVR automatically increase output
voltage 15% above input voltage if -9% to -25% of nominal. AVR
decrease output voltage 13% below input voltage if +9% to 25% of
nominal |
|
| AC Output Transfer |
2/4 milliseconds, including detection
time |
|
|
PROTECTION
|
|
| Protection Spike |
1050 joules (max.) |
|
| Protection Overload |
UPS automatical power off if overload
exceeds 110% of nominal at 60 seconds and 130% at 3 seconds |
|
| Protection Inside Protection |
UPS output cut off immediately or input
circuit breaker protection |
|
|
BATTERY
|
|
| Battery Type |
Sealed, maintenance-free lead acid |
|
| Battery Typical |
6 hours (to 90% of full capacity) |
|
| Battery Protection |
Auto discharge protection |
|
| Battery Run Time |
25 min |
|
|
PHYSICAL
|
|
| Physical Weight kgs |
6.3 |
|
| Physical Weight lbs |
13.88 |
|
| Physical Shipping Weight kgs |
6.8 |
|
| Physical Shipping Weight lbs |
14.97 |
|
| Physical Dimension mm |
105x334x168 |
|
| Physical Dimension inch |
4.1x13.1x6.6 |
|
| Physical Receptacles |
NEMA 5-15R (Battery:3, Bypass:3) |
|
|
|
|
ALARM
|
|
| Alarm Battery Backup |
Slow beeping sound (about 0.47HZ) |
|
| Alarm Battery Low |
Rapid beeping sound (about
1.824Hz) |
|
| Alarm Overload |
Continously beeping sound |
|
|
INTERFACE
|
|
| Interface Option |
USB |
|
|
ENVIRONMENT
|
|
| Environment Ambient |
3,500 meters max. elevation, 0-95%
humidity non-condensing, 0-40 deg C |
|
| Environment Audible |
<40dBA (1 meter from surface) |
|
| Environment Storage Condition |
15,000 meters max. elevation |
|
| ShowOrder |